Flotration Technologies
HomeAll documents

Results · Executive summary

ECT2 PFAS Bench Test — Executive Summary

May 2025 · ECT2 (now Onterris) · Independent RSSCT on client-representative water. You are still on flotration.com — use Results, Home, or Docs to leave anytime.

Key findings on this page

Independent rapid small-scale column testing (RSSCT) compared ion exchange with and without CAST pretreatment ahead of Dow PSR2+ resin. CAST is pretreatment — not a standalone PFAS-removal technology. Numbers below are from the public executive summary; full performance is site-specific and confirmed in a paid pilot.

  • PFOS bed life: about 13,767 bed volumes to 4 ng/L with CAST ahead of IX vs under about 1,619 without — more than eightfold longer run length before the USEPA MCL threshold (about 60 days vs 7 days at a 20 GPM design basis).
  • PFOA: similar delay in breakthrough at the same 4 ng/L basis in the CAST-plus-IX train.
  • Pressure: CAST influent built pressure slowly and ran continuously; without CAST, spikes required close daytime monitoring.
  • Lab: ECT2 (now Onterris) · report date May 15, 2025 · design basis 20 GPM · non-confidential summary; full laboratory report on request.

PDF preview

Preview not loading? Open the PDF in a new tab — this page stays open with Back and Home.